IG Lintels Ltd
Home Literature Projects Recruitment Contact Us

50-70mm Cavity Wall Lintels

L1/S 50

For 50-70mm cavity wall construction.
Standard duty loading condition.

List Price: www.iglintelsprices.com

L1/S 50
Note: Maximum block dimensions 125mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications.
* A continuous bottom plate added

Manufactured Length
150mm increments
0600
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
3150
3600
3750
4050
*4200
4800
Height ‘h’ 79 98 110 134 150 172 172 209 209 209
Thickness ‘t’ 1.6 2.0 2.0 2.0 2.0 2.0 2.6 3.2 3.2 3.2
Total UDL(kN) Load ratio (1) 12 14 19 21 21 26 27 27 26 27
Total UDL(kN) Load ratio (2) 10 12 16 17 19 22 20 20 19 22
L1/HD 50

For 50-70mm cavity wall construction.
Heavy duty loading condition.

List Price: www.iglintelsprices.com

L1/HD 50
Note: Maximum block dimensions 125mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications.
* A continuous bottom plate added

Manufactured Length
150mm increments
0600
1200
*1350
1500
*1650
2100
*2250
2550
*2700
3000
*3150
3600
*3750
4200
Height ‘h’ 105 121 171 209 209 209 209
Thickness ‘t’ 3.2 3.2 3.2 3.2 3.2 3.2 3.2
Total UDL(kN) Load ratio (1) 30 30 40 40 40 35 33
Total UDL(kN) Load ratio (2) 22 22 35 35 35 32 28
L1/XHD 50

For 50-70mm cavity wall construction.
Extra Heavy duty loading condition.

List Price: www.iglintelsprices.com

L1/XHD 50
Note: Maximum block dimensions 125mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications.
* A continuous bottom plate added

Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
Height ‘h’ 171 171 209
Thickness ‘t’ 3.2 3.2 3.2
Total UDL(kN) Load ratio (1) 50 50 55
Total UDL(kN) Load ratio (2) 45 45 45

Part Of The Keystone Group