50-100mm Cavity - Eaves Standard & Inner Leaf

L1/E 50
 

For 50-80mm (max) cavity wall construction. For use at eaves level.
Composite beam with blockwork.

List
Price:
www.iglintelsprices.com
  L1/E 50

Note:Maximum block dimensions 125mm (80mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
                                         
Height ‘h’
95
134
150
150
           
Thickness ‘t’
2
2
2
2.6
           
Total UDL(kN)
18
20
22
25
           


L1/E 75
 

For 70-100mm (max) cavity wall construction. For use at eaves level.
Composite beam with blockwork.

List
Price:
www.iglintelsprices.com
  L1/E 75

Note:Maximum block dimensions 125mm (100mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
                                         
Height ‘h’
95
134
150
150
           
Thickness ‘t’
2
2
2
2.6
           
Total UDL(kN)
18
20
22
25
           


L1/E WIL 50
 

For 50-80mm (max) cavity wall construction. For use at eaves level.
Composite beam with wide inner leaf blockwork.

List
Price:
www.iglintelsprices.com
  L1/E WIL 50

Note:Maximum block dimensions 150mm (80mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
                                         
Height ‘h’
91
136
136
150
           
Thickness ‘t’
2
2
2.6
2.6
           
Total UDL(kN)
18
20
25
20
           