95-110mm Cavity - Wide Inner Leaf

L1/S WIL 100
 

 

For 95-110mm cavity wall with wide inner block/brick construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1200
1350
1800
1950
2400
2550
3000
*3150
3600
*3750
4200
       
Height ‘h’ 82 107 142 177 188 188                            
Thickness ‘t’ 2 2 2 2.6 3.2 3.2                            
Total UDL(kN) Load ratio (1) 13 17 23 24 30 27                            
Total UDL(kN) Load ratio (2) 11 14 18 18 26 25                            

[Back to Top]

L1/HD WIL 100
 

 

For 95-110mm cavity wall with wide inner block/brick construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1200
*1350
1500
*1650
1800
*1950
2100
*2250
2700
         
Height ‘h’ 113 135 165 165 188                                   
Thickness ‘t’ 3.2 3.2 3.2 3.2 3.2                                   
Total UDL(kN) Load ratio (1) 20 25 35 30 36                                   
Total UDL(kN) Load ratio (2) 17 22 27 25 32                                   

[Back to Top]

L1/XHD WIL 100
 

 

For 95-110mm cavity wall with wide inner block/brick construction.
Extra heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
             
Height ‘h’ 165 188 188                                                 
Thickness ‘t’ 3.2 3.2 3.2                                                 
Total UDL(kN) Load ratio (1) 45 45 50                                                 
Total UDL(kN) Load ratio (2) 40 40 40                                                 
[Back to Top]


Return to Standard Lintel Range