70-95mm Cavity - Wide Inner Leaf

L1/S WIL 75
 

For 70-95mm cavity wall with wide inner block/brick construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1350
1500
1650

1800
1950
2100
2250
2400
2550
3000
*3150
3600
*3750
4200
   
Height ‘h’ 93 90 110 134 158 167 192 192              
Thickness ‘t’ 2 2 2 2 2 2.6 3.2 3.2              
Total UDL(kN) Load ratio (1) 12 13 20 19 24 27 30 27              
Total UDL(kN) Load ratio (2) 10 11 17 17 20 21 26 25              

[Back to Top]

L1/HD WIL 75
 

For 70-95mm cavity wall with wide inner block/brick construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1200
*1300
1500
*1650
1800
*1950
2100
*2250
2700
         
Height ‘h’ 93 107 157 157 192                                   
Thickness ‘t’ 3.2 3.2 3.2 3.2 3.2                                   
Total UDL(kN) Load ratio (1) 20 25 35 30 36                                   
Total UDL(kN) Load ratio (2) 17 22 27 25 32                                   

[Back to Top]

L1/XHD WIL 75
 

For 70-95mm cavity wall with wide inner block/brick construction.
Extra heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
             
Height ‘h’ 157 192 192                                                 
Thickness ‘t’ 3.2 3.2 3.2                                                 
Total UDL(kN) Load ratio (1) 45 45 50                                                 
Total UDL(kN) Load ratio (2) 40 40 40                                                 
[Back to Top]


Return to Standard Lintel Range