70-95mm Cavity Wall Lintels

L1/S 75
 

For 70-95mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
3000
3150
3600
3750
4050
*4200
4800
 
Height ‘h’ 98 89 106 130 142 168 204 204 204       
Thickness ‘t’ 1.6 2 2 2 2 2.6 3.2 3.2 3.2       
Total UDL(kN) Load ratio (1) 12 14 18 21 21 27 27 26 27       
Total UDL(kN) Load ratio (2) 10 12 14 17 19 22 20 19 22       

[Back to Top]

L1/HD 75
 

For 70-95mm cavity wall construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1200
*1350
1500
*1650
2100
*2250
2550
*2700
3000
*3150
3600
*3750
4200
   
Height ‘h’ 103 117 167 205 205 205 205                     
Thickness ‘t’ 3.2 3.2 3.2 3.2 3.2 3.2 3.2                     
Total UDL(kN) Load ratio (1) 30 30 40 40 40 35 33                     
Total UDL(kN) Load ratio (2) 22 22 35 35 35 32 28                     

[Back to Top]

L1/XHD 75
 

For 70-95mm cavity wall construction.
Extra heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
       
Height ‘h’ 167 167 205                                                 
Thickness ‘t’ 3.2 3.2 3.2                                                 
Total UDL(kN) Load ratio (1) 50 50 55                                                 
Total UDL(kN) Load ratio (2) 45 45 45                                                 
[Back to Top]