50-70mm Cavity - Wide Inner Leaf

L1/S WIL 50
 

For 50-70mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1350
1500
1650

1800
1950
2100
2250
2400
2550
3000
*3150
3600
*3750
4200
   
Height ‘h’ 91 96 110 136 162 172 196 196              
Thickness ‘t’ 2 2 2 2 2 2.6 3.2 3.2              
Total UDL(kN) Load ratio (1) 12 12 15 20 24 28 30 27              
Total UDL(kN) Load ratio (2) 10 10 13 18 20 21 26 25              

[Back to Top]

L1/HD WIL 50
 

For 50-70mm cavity wall construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1200
*1350
1500
*1650
1800
*1950
2100
*2250
2700
         
Height ‘h’ 95 110 161 161 196                                   
Thickness ‘t’ 3.2 3.2 3.2 3.2 3.2                                   
Total UDL(kN) Load ratio (1) 20 25 35 30 36                                   
Total UDL(kN) Load ratio (2) 17 22 27 25 32                                   

[Back to Top]

L1/XHD WIL 50
 

For 50-70mm cavity wall construction.
Extra Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 150mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
             
Height ‘h’ 161 196 196                                                 
Thickness ‘t’ 3.2 3.2 3.2                                                 
Total UDL(kN) Load ratio (1) 45 45 50                                                 
Total UDL(kN) Load ratio (2) 40 40 40                                                 
[Back to Top]