50-110mm Cavity - Heavy Duty Lintels

L5/50
 

 

For 50-70mm cavity wall construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 125mm (50mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1500
1650
2100
2250
3000
3150
4000
4200
4800
         
Height ‘h’ 229 229 229 229 229                                   
Thickness ‘t’ 2.9 2.9 2.9 3.2 3.2                                   
Total UDL(kN) Load ratio 19:1 70 60 50 45 40                                   

[Back to Top]

L5/75
 

 

For 70-95mm cavity wall construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 125mm (70mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications



Manufactured Length
150mm increments
0600
1500
1650
2100
2250
3000
3150
4000
4200
4800
         
Height ‘h’ 229 229 229 229 229                                   
Thickness ‘t’ 2.9 2.9 2.9 3.2 3.2                                   
Total UDL(kN) Load ratio 19:1 70 60 50 45 40                                   

[Back to Top]

L5/100
 

 

For 95-110mm cavity wall construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 125mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1500
1650
2100
2250
3000
3150
4000
4200
4800
         
Height ‘h’ 229 229 229 229 229                                   
Thickness ‘t’ 2.9 2.9 2.9 3.2 3.2                                   
Total UDL(kN) Load ratio 19:1 70 60 50 45 40                                   
[Back to Top]


Return to Standard Lintel Range