50-100mm Cavity - Eaves Standard & Inner Leaf

L1/E 50
 

 

For 50-80mm (max) cavity wall construction. For use at eaves level.
Composite beam with blockwork.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 125mm (80mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
           
Height ‘h’ 95 134 150 150                                          
Thickness ‘t’ 2 2 2 2.6                                          
Total UDL(kN) 18 20 22 25                                          

[Back to Top]

L1/E 75
 

 

For 70-100mm (max) cavity wall construction. For use at eaves level.
Composite beam with blockwork.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 125mm (100mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications



Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
           
Height ‘h’ 95 134 150 150                                          
Thickness ‘t’ 2 2 2 2.6                                          
Total UDL(kN) 18 20 22 25                                          

[Back to Top]

L1/E WIL 50
 

 

For 50-80mm (max) cavity wall construction. For use at eaves level.
Composite beam with wide inner leaf blockwork.

List
Price:
www.iglintelsprices.com
 

Note:Maximum block dimensions 150mm (80mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications


Manufactured Length
150mm increments
0600
1500
1650
2100
2250
2400
2550
2700
           
Height ‘h’ 91 136 136 150                                          
Thickness ‘t’ 2 2 2.6 2.6                                          
Total UDL(kN) 18 20 25 20                                          
[Back to Top]


Return to Standard Lintel Range