110-150mm Cavity Wall Lintels

L1/S 110
 

For 110-125mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (110mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2250
3000
*3150
4050
*4200
4800
       
Height ‘h’ 95 121 145 195 195 195                            
Thickness ‘t’ 2 2 2.6 2.9 3.2 3.2                            
Total UDL(kN) Load ratio (1) 16 22 24 27 26 25                            
Total UDL(kN) Load ratio (2) 13 18 18 22 19 20                            

[Back to Top]

L1/S 130
 

For 130-145mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (130mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications



Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2550
3000
*3150
4050
*4200
4800
       
Height ‘h’ 103 128 190 190 190 190                            
Thickness ‘t’ 2 2 2.6 2.9 3.2 3.2                            
Total UDL(kN) Load ratio (1) 16 22 24 27 26 25                            
Total UDL(kN) Load ratio (2) 13 18 18 22 19 20                            

[Back to Top]

L1/S 150
 

For 150-165mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
 

* A continuous bottom plate added Note:Maximum block dimensions 125mm (150mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2250
3000
*3150
*4050
4200
4800
       
Height ‘h’ 100 125 180 180 180 180                            
Thickness ‘t’ 2 2 2.6 2.9 3.2 3.2                            
Total UDL(kN) Load ratio (1) 16 22 24 27 26 25                            
Total UDL(kN) Load ratio (2) 13 18 18 22 19 20                            
[Back to Top]


Return to Standard Lintel Range